The other Chief Engineer Limited exam code: electrical and controls, steam plants, gas turbines. Your NMC approval letter says which you sit. Coast Guard exam code CEL02.
205 real questions from the Coast Guard National Maritime Center's public sample exams, free. Each module needs 70% to pass.
Passing score: Coast Guard pass marks module by module, and the retest rules
Start studying, freeOpens the Chief Engineer, Limited (CEL02) guide. No sign-up, nothing to install.What's free: daily rounds, the Brig, the drills and the Pass Meter, for every license. Your first module test is free too. After that, the full Exam Room is $19, once. No subscription.
| Module | Topic | Questions here | To pass |
|---|---|---|---|
| Q604 | Chief Engineer Limited: Electrical, Electronics & Control | 68 | 70% |
| Q605 | Chief Engineer Limited: Steam Plants | 69 | 70% |
| Q606 | Chief Engineer Limited: Gas Turbine Plants | 68 | 70% |
Picture questions link to the drawing in the Coast Guard's free sample PDF. A few that need reference tables are left out.
What is the maximum current allowed to be drawn from the secondary of a 2 kVA step-down transformer with a turns ratio of four to one if connected across a 440-volt line?
C. 18.1 amps
A four-stroke cycle auxiliary diesel engine fuel cam has shifted from its original position during maintenance. To ensure correct timing of the fuel pump, the intake and exhaust valves should be in what position when approaching top dead center for injection?
D. Intake and exhaust valves closed
Burner ignition failure in an automatically fired auxiliary boiler would be caused by __________.
A. a burned out solenoid in the oil supply valve
When measuring DC current flow using an analog or digital multimeter set up as a milliammeter, how is the meter connected?
B. in series with the power source and load
Which of the following locations could desuperheated steam be considered to occur?
C. Both "A" and "B"
A burner producing black smoke in an automatic auxiliary boiler, would be caused by a/an __________.
D. incorrect primary air setting
Prior to using an analog multimeter set up as an ohmmeter, the leads are purposely shorted together. Which of the following actions should be taken if, when adjusting to "zero" ohms, the indicating needle cannot be returned to "zero" on the scale?
A. The batteries should be replaced.
One advantage of installing water wall tubes in a boiler furnace is to __________.
A. decrease refractory maintenance
Heavy soot accumulations in an auxiliary boiler could be caused by __________.
D. improper burner maintenance
In what situation would an electrical phase sequence indicator be useful?
B. connecting shore power lines to the ship