Chief engineer on big fishing boats, processors and tenders (UFIV): motor plants, safety, general subjects. Coast Guard exam code UFIV01.
204 real questions from the Coast Guard National Maritime Center's public sample exams, free. Each module needs 70% to pass.
Passing score: Coast Guard pass marks module by module, and the retest rules
Start studying, freeOpens the Chief Engineer, Uninspected Fishing Industry Vessels guide. No sign-up, nothing to install.What's free: daily rounds, the Brig, the drills and the Pass Meter, for every license. Your first module test is free too. After that, the full Exam Room is $19, once. No subscription.
| Module | Topic | Questions here | To pass |
|---|---|---|---|
| Q694 | Chief Engineer UFIV: Motor Plants | 67 | 70% |
| Q696 | Chief Engineer UFIV: Safety & Environmental Protection | 70 | 70% |
| Q697 | Chief Engineer UFIV: General Subjects | 67 | 70% |
Picture questions link to the drawing in the Coast Guard's free sample PDF. A few that need reference tables are left out.
The tube sheets installed in a fire-tube auxiliary boiler are normally connected by __________.
B. fire-tubes and stay-tubes
A tank has been sealed and unventilated for a long period of time. Which of the following statements is true?
C. The tank is especially dangerous to enter.
In general, the thermal bulb for a thermal expansion valve used in a reciprocating air conditioning system is usually charged with what substance?
C. the same refrigerant as the system
The primary function of a flame safeguard system, as used on an automatically fired auxiliary boiler, is to prevent __________.
C. explosions in the boiler furnace
Fire detecting systems on merchant vessels may be arranged to sense __________.
D. all of the above
When a refrigeration system is being topped off with a small amount of refrigerant through the low side with the compressor running, what should be done?
D. the refrigerant should be charged into the system as a vapor
Which of the following fuel systems is characterized by a complete absence of high-pressure fuel lines?
B. Unit injector type system
You notice smoke coming from an open laundry room doorway, which smells like electrical insulation. After activating the fire alarm, which of the following would be the lowest action priority?
B. Break out the nearest fire hose.
Which of the following statements describes the characteristics of precision manufactured roller bearings?
B. They are well adapted to variable speed operation.
When checking the crankcase oil level on a main propulsion engine on your fishing industry line vessel while underway, what should be the oil level as indicated on the dipstick?
B. The level should be between the "full" and "add" marks on the side of the dipstick marked with engine IDLE and oil HOT.